Model ACSⅡ series
Model ACSⅡ series products are temperature calibration systems for surface temperature and internal temperature measuring devices.
Temperatures can be set across a wide range, from room temperature to 500°C. These calibration systems are designed for calibration, or to check temperature measuring probes.
ACSⅡ-1000 For Surface Temperature
Max. 572°F (300°C)
Max. 572°F (300°C)
ACSⅡ-2000 For Surface Temperature
Max. 932°F (500°C)
Max. 932°F (500°C)
Please specify a power supply voltage when ordering (choose from 100 VAC, 115 VAC, or 230 VAC).
Please contact us for help in selecting the best calibrator for your application and to receive a quote. Call 504-316-9527, or email [email protected].
Specifications
Overall Accuracy
Model | ACSⅡ-1000 | ACSⅡ-2000 | ACSⅡ-3000 | ACSⅡ-4000 | ||
Calibration Object | Surface | Internal | Surface | Internal | ||
Range | Rt to 100°C | +0.5 / -0.7°C | +0.5 / -0.7°C | ±0.26°C | +0.4 / -0.6°C | ±0.26°C |
100 to 200°C | +0.5 / -1.1°C | +0.5 / -1.1°C | ±0.32°C | +0.3 / -0.9°C | ±0.32°C | |
200 to 300°C | +0.5 / -1.5°C | +0.5 / -1.5°C | ±0.37°C | +0.1 / -1.1°C | ±0.37°C | |
300 to 400°C | — | +0.4 / -2.0°C | ±0.43°C | +0.2 / -1.5°C | ±0.43°C | |
400 to 500°C | — | -0.1 / -2.9°C | ±0.48°C | -0.9 / -2.2°C | ±0.48°C |
Control Unit
Model | ACSⅡ-1000 | ACSⅡ-2000 | ACSⅡ-3000 | ACSⅡ-4000 | |
Surface Range | Rt to 300°C | Rt to 500°C | — | Rt to 500°C | |
Internal Range | — | — | Rt to 500°C | Rt to 500°C | |
Control Principle | PID auto-Tuning Control | ||||
Control | Input | Pt 100Ω, ø3.2 Class A | |||
Accuracy | ±(0.2% of reading)°C | ||||
Display | 8mm high LED display | ||||
Reference Sensor |
Input | — | Pt 100Ω, ø4.8 Class A | ||
Accuracy | — | ±(0.05% of reading +0.05)°C | |||
Display | — | 12.5mm high LED display | |||
Power Consumption | App.160W | App.700W | App.1600W | ||
Dimensions (mm) | 320(W)×177(H)×350(D) | 430(W)×177(H)×350(D) | |||
Weight | App.4.5kg | App.5.0kg |
Calibration Unit
Model | ACSⅡ-1000 | ACSⅡ-2000 | ACSⅡ-3000 | ACSⅡ-4000 |
Testing Surface (mm) | ø78 | ø100 | — | 150×150 |
Test Point | — | — | 8 holes based on specified dimension | |
Temp. Distribution | ±0.1°C | |||
Heater | 150W | 600W | 1500W | |
Dimensions (mm) | 260(W)×130(H)×260(D) | 390(W)×230(H)×360(D) | 450(W)×405(H)×400(D) | |
Weight | App.7kg | App.20kg | App.70kg | |
Overheating prevention mechanism | Bimetal breaker | |||
Heating time | Rt → 150°C 20min | Rt → 250°C 20min | Rt → 250°C 60min | |
Rt → 300°C 40min | Rt → 500°C 50min | Rt → 500°C 150min | ||
Cooling time | 300 → 150°C 20min | 500 → 250°C 30min | 500 → 250°C 220min | |