![How to order of STN series](http://www.anritsu-meter.com/probe/images/stn.gif)
![How to order of STN series](http://www.anritsu-meter.com/probe/images/order_stn.gif)
![]() |
Tape width and shape | 1 | Standard type : Sharp |
2 | Standard type : Flat | ||
3 | Narrow type : Sharp | ||
4 | Narrow type : Flat | ||
![]() |
Coating type and operating temperature range |
1 | Low temperature : Teflon coating (open) |
2 | Low temperature : All teflon coating | ||
3 | High temperature : Polyimide coating (open) | ||
4 | High temperature : All polyimide coating | ||
![]() |
Thermocouple | K | Chromel-Alumel |
E | Chromel-Constantan | ||
![]() |
Tape length | 003 | 30mm |
005 | 50mm | ||
008 | 80mm | ||
010 | 100mm | ||
… | …… | ||
200 | 2000mm |
![How to order of STN cable](http://www.anritsu-meter.com/probe/images/stn_cable_order.gif)
An extension cable is required for the tape replaceable type
How to order extension cable
![number 1](http://www.anritsu-meter.com/probe/images/1.gif)
You can choose junction from as below.
Tape width : Standard type
![Sharp or Flat](http://www.anritsu-meter.com/probe/images/stn_standard.gif)
Tape width : Narrow type
![Sharp or Flat](http://www.anritsu-meter.com/probe/images/stn_narrow.gif)
![number 2](http://www.anritsu-meter.com/probe/images/2.gif)
You can choose coating type as below.
Low temperature : Teflon coating (Open)
STN-*1 Temp.range : -50 to 210°C
STN-*1 Temp.range : -50 to 210°C
![Coating Type and operating temperature range](http://www.anritsu-meter.com/probe/images/stn_coa_temp_0.gif)
Low temperature : All teflon coating
STN-*2 Temp.range : -50 to 210°C
STN-*2 Temp.range : -50 to 210°C
![Coating Type and operating temperature range](http://www.anritsu-meter.com/probe/images/stn_coa_temp_1.gif)
High temperature : Polyimide coating (Open)
STN-*3 Temp.range : -50 to 400°C
STN-*3 Temp.range : -50 to 400°C
Max. temperature of 350℃ when the tape length exceeds 150mm
![Coating Type and operating temperature range](http://www.anritsu-meter.com/probe/images/stn_coa_temp_2.gif)
High temperature : All polyimide coating
STN-*4 Temp.range : -50 to 400°C
STN-*4 Temp.range : -50 to 400°C
Max. temperature of 350℃ when the tape length exceeds 150mm
![Coating Type and operating temperature range](http://www.anritsu-meter.com/probe/images/stn_coa_temp_3.gif)
![number 4](http://www.anritsu-meter.com/probe/images/4.gif)
You can choose tape length as below.
003 : 30mm | 030 : 300mm | 080 : 800mm |
005 : 50mm | 035 : 350mm | 090 : 900mm |
008 : 80mm | 040 : 400mm | 100 : 1000mm |
010 : 100mm | 045 : 450mm | 150 : 1500mm |
015 : 150mm | 050 : 500mm | 200 : 2000mm |
020 : 200mm | 060 : 600mm | |
025 : 250mm | 070 : 700mm |
Specifications
Tolerance | Open : ±2.5°C (at 100°C) All coating : ±2.5°C (at 100°C) |
Response time | Open : 2.0 s All coating : 8.0 s |
Durability rank | S |
Attention
Where the probes are not glued or inserted, the operating temperature limits as follows:
STN-*1 | STN-*2 | STN-*3 | STN-*4 | |
Tape ≦ 150mm | 200°C | 180°C | 200°C | 200°C |
Tape > 150mm | 200°C | 180°C | 180°C | 180°C |
Tolerance
* : Number
■ : Thermocouple type K or E
t : Measured temperature
■ : Thermocouple type K or E
t : Measured temperature
STN-*1■ / STN-*2■
Temperature range | Tolerance (Internal) |
-50°C ≦ t < -40°C | ±3.5°C |
-40°C ≦ t ≦ 210°C | ±2.5°C |
STN-*3■ (Tape length ≦ 150mm)
STN-*4■ (Tape length ≦ 150mm)
STN-*4■ (Tape length ≦ 150mm)
Temperature range | Tolerance (Internal) |
-50°C ≦ t < -40°C | ±3.5°C |
-40°C ≦ t < 333°C | ±2.5°C |
333°C ≦ t ≦ 400°C | ±(0.0075╳|t|)°C |
STN-*3■ (Tape length > 150mm)
STN-*4■ (Tape length > 150mm)
STN-*4■ (Tape length > 150mm)
Temperature range | Tolerance (Internal) |
-50°C ≦ t < -40°C | ±3.5°C |
-40°C ≦ t < 333°C | ±2.5°C |
333°C ≦ t ≦ 350°C | ±(0.0075╳|t|)°C |