Pipe (Outside) Probes

These probes are ideal for measuring the temperatures of surfaces having a small-radius bend, such as pipes. Choose the most appropriate guard, based on the diameter of the measurement target.

Most probes come in either Type K (Cromel-Alumel), or Type E (Nickel-Chromium/Constantan). Specific parts of this probe, like the cable length and pipe length can be customized for your specific application. Please contact us for help in configuring the design for probe and to receive a quote. Call 504-316-9527, or email [email protected].

How to Order a Series K Pipe (Outside) Probe

Type K Model 123K-φ50-TC1-ANP
Type E Model 123E-φ50-TC1-ANP
Pipe outside probes
Temp. Range Tolerance Response time Durability
-50 to 250°C ±2.5°C * 2.0 s B
* at 100°C Surface
Tolerance
■ : Thermocouple type K or E
t : Measured temperature
Model 123■
Temperature range Tolerance (Surface)
0°C ≦ t ≦ 200°C ±2.5°C
200°C < t ≦ 250°C ±3.5°C
These probes are ideal for measuring the temperatures of surfaces having a small-radius bend, such as pipes.
Choose the most appropriate guard, based on the diameter of the measurement target.
Guard form Producible range Tolerance when specified
φ9 to 15mm ±1mm
φ16 to 39mm ±2mm
φ40 to 100mm ±5mm
Type K Model 528K-TC1-ANP
Type E Model 528E-TC1-ANP
Pipe outside probes
Temp. Range Tolerance Response time Durability
-50 to 210°C ±2.5°C * 3.0 s B
* at 100°C Surface
Tolerance
■ : Thermocouple type K or E
t : Measured temperature
Model 528■
Temperature range Tolerance (Internaal)
0°C ≦ t ≦ 210°C ±2.5°C
Type K Model 1811K-TS1-ANP
Type E Model 1811E-TS1-ANP
Pipe outside probes
Temp. Range Tolerance Response time Durability
-50 to 100°C ±2.5°C * 2.0 s S
* at 100°C Surface
Tolerance
■ : Thermocouple type K or E
t : Measured temperature
Model 1811■
Temperature range Tolerance (Surface)
0°C ≦ t ≦ 100°C ±2.5°C
Thermocouple type Choose type K or Type E

Be sure to choose the same thermocouple type as the one used for the main thermometer unit.

Cable Length Length of cord section Specify a cord length in 1m increments.
Plug Choose ANP (US Mini Connector) or ASP (Japanese (Anritsu) Standard))

Be sure to choose the same plug type as the one used for the main thermometer unit.

Attention
The following probes have certain restrictions on customization.
Model No. Restrictions
619, 620, 621 These probes are Type K only.