| Thermocouple | K | Chromel-Alumel | |
| E | Chromel-Constantan | ||
| Thermocouple length | 050 | 500mm | |
| 100 | 1000mm | ||
| 150 | 1500mm | ||
| 200 | 2000mm | ||
| Plug see plug page |
ANP | ||
| ASP | |||
| W |

This probe does not incorporate compensating lead wires.
Specifications
| Tolerance | ±2.5°C (at 100°C) |
| Response time | 2.0 s |
| Durability rank | S |
| Max. Temp. | 200°C |
Tolerance
■ : Thermocouple type K or E
t : Measured temperature
t : Measured temperature
SF-■
| Temperature range | Tolerance (Internal) |
| -50°C ≦ t < -40°C | ±3.5°C |
| -40°C ≦ t ≦ 200°C | ±2.5°C |