Form | A | Grip type | |
B | Sleeve type | ||
C | Terminal box type | ||
AH | Grip type/Teflon coating | ||
BH | Sleeve type/Teflon coating | ||
CH | Terminal box type/Teflon coating | ||
Diameter | 0.25 | φ0.25mm | |
0.5 | φ0.5mm | ||
1.0 | φ1.0mm | ||
1.6 | φ1.6mm | ||
3.2 | φ3.2mm | ||
4.8 | φ4.8mm | ||
6.4 | φ6.4mm | ||
8.0 | φ8.0mm | ||
Thermocouple Type | K | Chromel-Alumel | |
E | Chromel-Constantan | ||
Junction | J1 | Grounded junction | |
J2 | Ungrounded junction | ||
J3 | Exposed junction | ||
Material | M1 | SUS 316 | |
M2 | SUS 310S (Only type K) | ||
M3 | Inconel (Only type K) | ||
Sheath Length | L100 | 100mm | |
L200 | 200mm | ||
… | …… | ||
Cable Type see cable page |
TC | More than φ1mm in sheath diameter | |
TS | φ0.25mm,φ0.5mm in sheath diameter | ||
Cable Length | 1 | 1000mm | |
1.5 | 1500mm | ||
2 | 2000mm | ||
… | …… | ||
Plug see plug page |
ANP | ||
ASP | |||
W |
Form
You can choose Form as below.
Models with an outer sheath diameter of φ0.25 / 0.5mm have sleeve dimensions of φ5 × 30mm and no spring.
Junction
Supplementary information
The sheath tube can be coated with Teflon.
Teflon coating will improve resistance against chemicals and enable the use of the probe for measuring the temperatures of acids alkalis, food. etc.
Applicable sheath diameter : φ1.0, φ1.6, φ3.2
Maximum length : 1m
Operating temperature limit : 200°C
Minimum bending radius : Approx. 10mm
Specifications
Outside diameter (mm) | 0.25 | 0.5 | 1.0 | 1.6 | 3.2 | 4.8 | 6.4 | 8.0 | |
Type : K Max.temp.(°C) | SUS316(M1) | — | — | 650 | 650 | 750 | 800 | 800 | 900 |
SUS310S(M2) | — | — | 650 | 650 | 750 | 800 | 800 | 900 | |
Inconel(M3) | 500 | 500 | 650 | 650 | 750 | 900 | 1000 | 1050 | |
Type : E Max.temp.(°C) | SUS316(M1) | — | — | 650 | 650 | 750 | 800 | 800 | 800 |
Response time (sec.) | 0.4 | 0.9 | 2 | 3 | 5 | 10 | 15 | 20 | |
Standard resistance (Ω / m) | Type : K | 570 | 124 | 32 | 13 | 4 | 2.2 | 1.0 | 0.7 |
Type : E | — | ― | 38 | 15 | 5 | 2.6 | 1.2 | 0.9 | |
Max. Length (m) | J1, J3 | 5 | 10 | 50 | 50 | 50 | 50 | 30 | 20 |
J2 | 2 | 2 | 2 | 5 | 15 | 30 | 30 | 20 | |
Tolerance | Type : K | -40 to 333°C : ±2.5°C, 333 to 1200°C : ±(measuring×0.75%)°C | |||||||
Type : E | -40 to 333°C : ±2.5°C, 333 to 900°C : ±(measuring×0.75%)°C |
Avoid immersing these probes in molten aluminum. Doing so may result in corrosion of the sheathed sensor.
Make sure that the sum of the sheath and code resistance values does not exceed the value of the signal source resistance of the instrument body.
Tolerance
* : Number
■ : Thermocouple type K or E
t : Measured temperature
■ : Thermocouple type K or E
t : Measured temperature
A0.25-K / A0.5-K / B0.25-K / B0.5-K
Temperature range | Tolerance (Internal) |
-40°C ≦ t < 333°C | ±2.5°C |
333°C ≦ t ≦ 500°C | ±(0.0075×|t|)°C |
A1.0-■ / A1.6-■ / B1.0-■ / B1.6-■ / C1.0-■ / C1.6-■
Temperature range | Tolerance (Internal) |
-40°C ≦ t < 333°C | ±2.5°C |
333°C ≦ t ≦ 650°C | ±(0.0075×|t|)°C |
A3.2-■ / B3.2-■ / C3.2-■
Temperature range | Tolerance (Internal) |
-40°C ≦ t < 333°C | ±2.5°C |
333°C ≦ t ≦ 750°C | ±(0.0075×|t|)°C |
A4.8-■-J*-M1 / A4.8-K-J*-M2
A6.4-■-J*-M1 / A6.4-K-J*-M2 / A8.0-E-J*-M1
B4.8-■-J*-M1 / B4.8-K-J*-M2
B6.4-■-J*-M1 / B6.4-K-J*-M2 / B8.0-E-J*-M1
C4.8-■-J*-M1 / C4.8-K-J*-M2
C6.4-■-J*-M1 / C6.4-K-J*-M2 / C8.0-E-J*-M1
A6.4-■-J*-M1 / A6.4-K-J*-M2 / A8.0-E-J*-M1
B4.8-■-J*-M1 / B4.8-K-J*-M2
B6.4-■-J*-M1 / B6.4-K-J*-M2 / B8.0-E-J*-M1
C4.8-■-J*-M1 / C4.8-K-J*-M2
C6.4-■-J*-M1 / C6.4-K-J*-M2 / C8.0-E-J*-M1
Temperature range | Tolerance (Internal) |
-40°C ≦ t < 333°C | ±2.5°C |
333°C ≦ t ≦ 800°C | ±(0.0075×|t|)°C |
A4.8-K-J*-M3 / A8.0-K-J*-M1 / A8.0-K-J*-M2
B4.8-K-J*-M3 / B8.0-K-J*-M1 / B8.0-K-J*-M2
C4.8-K-J*-M3 / C8.0-K-J*-M1 / C8.0-K-J*-M2
B4.8-K-J*-M3 / B8.0-K-J*-M1 / B8.0-K-J*-M2
C4.8-K-J*-M3 / C8.0-K-J*-M1 / C8.0-K-J*-M2
Temperature range | Tolerance (Internal) |
-40°C ≦ t < 333°C | ±2.5°C |
333°C ≦ t ≦ 900°C | ±(0.0075×|t|)°C |
A6.4-K-J*-M3 / B6.4-K-J*-M3 / C6.4-K-J*-M3
Temperature range | Tolerance (Internal) |
-40°C ≦ t < 333°C | ±2.5°C |
333°C ≦ t ≦ 1000°C | ±(0.0075×|t|)°C |
A8.0-K-J*-M3 / B8.0-K-J*-M3 / C8.0-K-J*-M3
Temperature range | Tolerance (Internal) |
-40°C ≦ t < 333°C | ±2.5°C |
333°C ≦ t ≦ 1050°C | ±(0.0075×|t|)°C |
AH**-■ / BH**-■ / CH**-■
Temperature range | Tolerance (Internal) |
-40°C ≦ t ≦ 200°C | ±2.5°C |